AuxTel M1 Cover Fails to Open#
Overview#
This procedure explains the steps to follow when AuxTel M1 Cover fails to open during daytime checkout or at the start of night.
Error Diagnosis#
This is possible following any daytime work which involves manually controlling the M1 Covers on AuxTel, such as the weekly C02 mirror cleaning.
auxtel/daytime_checkout/atpneumatics_checkout.py fails with:
atpneumatics_checkout.py#  Error in run Traceback (most recent call last):
  File "/opt/lsst/software/stack/conda/envs/lsst-scipipe-7.0.1/lib/python3.11/site-packages/lsst/ts/salobj/base_script.py",
  line 603, in do_run await self._run_taskFile "/net/obs-env/auto_base_packages/ts_standardscripts/python/lsst/ts/standardscripts/auxtel/daytime_checkout/atpneumatics_checkout.py",
  line 200, in run await self.atcs.open_m1_cover()File "/net/obs-env/auto_base_packages/ts_observatory_control/python/lsst/ts/observatory/control/auxtel/atcs.py",
  line 1074, in open_m1_cover
  await self.rem.atpneumatics.cmd_openM1Cover.start(timeout=self.long_timeout)File "/opt/lsst/software/stack/conda/envs/lsst-scipipe-7.0.1/lib/python3.11/site-packages/lsst/ts/salobj/topics/remote_command.py", line 487, in start
  return await cmd_info.next_ackcmd(timeout=timeout)
  File "/opt/lsst/software/stack/conda/envs/lsst-scipipe-7.0.1/lib/python3.11/site-packages/lsst/ts/salobj/topics/remote_command.py", line 191, in next_ackcmd
  raise base.AckError(msg="Command failed", ackcmd=ackcmd)
  lsst.ts.salobj.base.AckError: msg='Command failed', ackcmd=(ackcmd private_seqNum=1568846216, ack=<SalRetCode.CMD_FAILED: -302>,
  error=0, result='ERROR: Command OPENM1COVER rejected while M1 covers controller in StandbyState state.')
Post-Condition#
This procedure leaves the telescope with the M1 cover open.
Procedure Steps#
The recovery of the M1 cover control must be done from the ATMCS EUI.
- Ensure the ATCS CSCs are all set to STANDBY - The easiest way to do this is to run the - standby_atcs.pyscript from the ATQueue. Do not proceed to the next step until the CSCs are set to- STANDBY, otherwise you will need to reset both the CSC and EUI to regain communication.
- Log in to the ATMCS EUI either using a remote desktop or from the control computer on the first floor of the AuxTel dome. - More instruction can be found in the access ATMCS EUI procedure. 
- Close the ATMCS EUI tab 
- Engage E-stop in main AT Control Cabinet and ATDome Main Box located on the first floor. 
- Release E-stop starting with the ATDome Main Box followed by the AT Control Cabinet. - Refer to release E-stop procedure for more details. 
- Open LSST Auxiliary Telescope MCS & Pneumatics EUI aka ATMCS in the web-browser. - Address is http://139.229.170.47:8000/atmcs.html   - ATMCS EUI#