LATISS Daily Calibrations BIAS, DARK and FLAT: all filters + empty

Overview

This procedure will enable and turn on the ATWhiteLight that illuminates the dome flat screen. It will position the telescope and dome in the FLAT position, and will take BIAS, DARK, and FLATS calibrations images in all installed filters including the empty filter. Finally will turn off the white light and send the ATWhiteLight to STANDBY. After the entire script completion, the telescope and dome will remain in ENABLED state and in the FLAT field position. The observer can decide whether to vent, proceed to on-sky or shutdown.

This page assumes the reader is familiar with the content explained in the Observatory section: Introduction to the combined calibrations generation procedure

Warning

This procedure involves telescope motion with AuxTel. Be sure to confirm the dome is clear of personnel and announce that you are going to run the calibrations with telescope movement on the #summit-announce and #summit-auxtel channels before you run the following steps. The whole process takes about 1.5 hours.

Post-Condition

  • Individual calibration images will be taken and verified using the cp_verify framework.

  • If generate_calibrations is True, a (daily) combined calibration image per detector will be certified in a butler CALIBRATION collection.

Procedure Steps

  1. Enable ATCS and LATISS using the standard scripts enable_atcs.py and enable_latiss.py with no configuration.

  2. Enable Scheduler:2 with a valid scheduler configuration. Use the standard script auxtel/scheduler/enable.py with the configuration specified in the AuxTel Scheduler-Driven Survey Test Case (BLOCK-T19).

  3. Setup LATISS calibrations BLOCK will setup ATCS and white light for calibrations. It enables and turns on the ATWhiteLight, enables OCPS:1 and commands AuxTel mount and dome to the FLAT position. Run the script add_block.py to the ATQueue with the following configuration:

    add_block.py
    id: BLOCK-309
    

    The BLOCK with setup_latiss_calibrations configuration will queue the scripts aimed to setup the system. It will start with the set_summary_state.py script to enable ATWhiteLight CSC with the following configuration:

    set_summary_state.py
    data:
      -
        - ATWhiteLight
        - ENABLED
    

    The set_summary_state.py script will enable OCPS:1 CSC.

    set_summary_state.py
    data:
      -
        - OCPS:1
        - ENABLED
    

    The SAL script auxtel/calibrations/power_on_atcalsys.py with no configuration inserted into the BLOCK setup_latiss_calibrations structure will start the chiller, turn on the white light and open the shutter. This script takes 15 minutes to complete, the time it takes to warm up the white light. On Chronograf using the query lsst.sal.ATWhiteLight.logevent_logMessage.message, the lamp reports its retry loop status explicitly.

    auxtel/calibrations/power_on_atcalsys.py
    
    

    The auxtel/prepare_for/flat.py script (empty configuration) will position the telescope and dome in FLAT position. The telescope will point towards the dome flat screen (mount Az = 188.7 deg, mount El = 39.0 deg, dome Az= 2.59 deg). Confirm in the cameras “aux-cam01” or “aux-cam02” that the white light is on, and telescope is pointing to the dome flat screen.

    auxtel/prepare_for/flat.py
    
    
  4. The LATISS daily calibrations BLOCK will queue the scripts focused on the calibration image acquisition. Run the script add_block.py to the ATQueue with the following configuration:

    add_block.py
    id: BLOCK-295
    

    Depending on which filters are currently installed in LATISS, the auxtel/make_latiss_calibrations.py script may take different calibration sets. The calibration images displayed in RubinTV are post-ISR images and should have BIAS and DARK corrections applied. This means that BIAS and DARK images should display with maximum count rates of about 10 ADUs. In the case of FLAT images, counts must be below the \(\approx\) 30000 ADUs. In the process of building the daily PTC (see below), the FLAT saturation is intended, and achieved at around the 123000 ADUs (with exposure time of about 25 seconds). In case daily FLATS are taken, they reach values of \(\approx\) 68000 ADUs. If you see large deviations from these values, which can be related with a problem in the instrument signature removal in RubinTV, then RAW count rates are being displayed, please report it. Check the calibration sets and their configurations for each filter installed and the grating.

    1. : Set configuration for SDSSr_65mm.

    auxtel/make_latiss_calibrations.py
      n_flat: 20
      exp_times_flat: 6
      script_mode: BIAS_DARK_FLAT
      filter: SDSSr_65mm
      grating: empty_1
    
    1. : Set configuration for SDSSg_65mm.

    auxtel/make_latiss_calibrations.py
      n_bias: 3
      n_dark: 3
      exp_times_dark: 6
      n_flat: 20
      exp_times_flat: 6
      script_mode: BIAS_DARK_FLAT
      filter: SDSSg_65mm
      grating: empty_1
    
    1. : Set configuration for SDSSz_65mm.

    auxtel/make_latiss_calibrations.py
      n_bias: 3
      n_dark: 3
      exp_times_dark: 6
      n_flat: 20
      exp_times_flat: 3
      script_mode: BIAS_DARK_FLAT
      filter: SDSSz_65mm
      grating: empty_1
    
    1. : Set configuration for SDSSy_65mm.

    auxtel/make_latiss_calibrations.py
      n_bias: 3
      n_dark: 3
      exp_times_dark: 6
      n_flat: 20
      exp_times_flat: 30
      script_mode: BIAS_DARK_FLAT
      filter: empty_1
      grating: SDSSy_65mm
    
    1. : Set configuration for empty_1.

    auxtel/make_latiss_calibrations.py
      n_bias: 3
      n_dark: 3
      exp_times_dark: 1
      n_flat: 20
      exp_times_flat: 1
      script_mode: BIAS_DARK_FLAT
      filter: empty_1
      grating: empty_1
    
    1. : Set sequence for the daily Photon Transfer Curve (PTC). Skip it if the previous sets were queued manually.

    auxtel/take_image_latiss.py
      image_type: FLAT
      filter: SDSSr_65mm
      grating: empty_1
      reason: daily_PTC
      exp_times:
              0.25,
              0.25,
              1.42,
              1.42,
              6.53,
              6.53,
              4.23,
              4.23,
              30.04,
              30.04,
              12.56,
              12.56,
              57.75,
              57.75,
              8.13,
              8.13,
              2.73,
              2.73,
              3.40,
              3.40,
              1.77,
              1.77,
              111.03,
              111.03,
              37.35,
              37.35,
              0.48,
              0.48,
              0.59,
              0.59,
              10.10,
              10.10,
              1.14,
              1.14,
              0.20,
              0.20,
              89.29,
              89.29,
              71.81,
              71.81,
              0.38,
              0.38,
              0.31,
              0.31,
              19.43,
              19.43,
              2.20,
              2.20,
              15.62,
              15.62,
              0.92,
              0.92,
              0.74,
              0.74,
              24.16,
              24.16,
              5.25,
              5.25,
              46.44,
              46.44
    
    1. : Set sequence for daily_flats.

    auxtel/take_image_latiss.py
      image_type: FLAT
      filter: SDSSr_65mm
      grating: empty_1
      reason: daily_sflat,
      exp_times:
                      0.5,
                      0.5,
                      0.5,
                      0.5,
                      0.5,
                      12.8,
                      12.8,
                      12.8,
                      12.8,
                      12.8
    
  5. The Shutdown LATISS calibrations BLOCK will turn off the calibration lamp and leave it on standby state. Run the script add_block.py to the ATQueue with the following configuration:

    add_block.py
    id: BLOCK-310
    

    The BLOCK with shutdown_latiss_calibrations configuration finishes with the auxtel/calibrations/power_off_atcalsys.py SAL script with no configuration. It will turn off the lamp, close the shutter and shutdown the chiller. At this stage, the script completion time is 15 minutes.

    auxtel/calibrations/power_off_atcalsys.py
    
    

    Finally, the set_summary_state.py script sends ATWhiteLight back to STANDBY.

    set_summary_state.py
      data:
        -
         - ATWhiteLight
         - STANDBY
    

Once the last script is done, check the camera to make sure the white light is off. At this point, ATCS and LATISS are in ENABLED state and the dome and telescope are in FLAT position.

Note

The location of the BLOCK source code can be checked and if the filters or exposures times have changed, create a ticket for yourself and edit this document accordingly.

Contingency

In cases such as telescope and dome movement not allowed or not cleared, or not enough time available for calibrations, skip this procedure.

This procedure was last modified Dec 15, 2024.