E-Stop Procedure#
Overview#
The emergency stop procedure plays a crucial role in ensuring the safety of Rubin Observatory. It is typically used in emergency situations or as a safety measure. It works by cutting off the electrical power to the various components of the telescope, including the mount and dome, which stops them from being moved either by software commands or manually.
The emergency stop can be triggered by users in certain circumstances, but it can also be activated automatically in the event of strong earthquakes (currently not implemented), as well as in response to safety interlocks and software-based emergencies. While the primary objective of the emergency E-stop procedure is to provide a quick and reliable means of halting the movement of the telescope and dome to avoid accidents and injuries, it also serves the purpose of safeguarding the system.
Below you will find a brief overview of the emergency stop procedure, covering:
Where to Find the E-stop Switches#
The emergency stop system in the Auxiliary Telescope can be triggered from three different locations.
One is located in the main AT Control Cabinet
on the first floor just in from of the working desktops.
A second one is located in the Dome Control Box
between vent gates #3 and #4, also in the first floor.
Both systems can be used to either engage and/or disengage the emergency stop.
Additionally, a third emergency stop button is available upstairs in the control box used for manual movement of the dome components,
as illustrated in the accompanying figure.
It is worth noting, however, that this control box can only be used to initiate the emergency stop and cannot be used to release it,
as it does not have a Start
button on it.
In the future, a physical emergency stop button will also be added to the Control Room. For now, the emergency E-stop system available there will only work for the main telescope components. The only way to activate the E-stop system for the Auxiliary Telescope is by doing it physically on site itself.
Note
The system is smart enough to allow an independent operation, meaning that you can disengage the emergency stop from any location, regardless of where it was initially triggered. When the emergency stop is activated, it will cut power to the telescope and dome drives, but it will not affect the functionality of instruments, communication, and calibration systems. It means you can continue taking images (e.g. LATISS + Calibration System) even if the emergency stop system has been activated.
How to Engage/Disengage the E-stop System#
Engaging the emergency stop system is a straightforward process that is both efficient and reliable. To trigger it, simply push the big red button. This will be enough to stop halt the telescope and avoid it from accidental/unexpected movements. To release it, simply turn the big red E-stop button clockwise a quarter or so and then push the blue Start button.
Verifying the Status of the E-stop System#
In order to verify that the emergency stop system was properly engaged, you just have to look at the computer located on the first floor of the AuxTel building. If the emergency stop was correctly triggered, you will see under the Mount status tab that its indicator will light up red, as depicted in the accompanying figure. Conversely, when the emergency stop is released, the red light will be turned off, indicating that the system has been successfully restarted. From that point onwards, the telescope will be released to move, either local or remotely, meaning it is ready for normal operation.
If you open the AT Control Cabinet
, you may see what is shown in the figure above.
The three LEDs brightly illuminated are indicating that the E-stop system is released and that the AuxTel telescope can be moved.
Important
In case of failures, you should contact an electronics technician to recover the E-stop system. Do not try to fix it by yourself.